Valve length and overall height of the structure of small, open and close fast, and has a good flow control characteristics, the structural principle of the best butterfly production of large diameter valves. When asked to use the valve for flow control, the most important right choice when the valve size and type, so that it can properly and effectively work.
Typically, the throttle, adjusting the medium control and mud, requiring a short length of the structure, opening and closing speed (1 / 4 turn). Low cut-off (pressure difference), recommended use butterfly.
In the double-digit adjusted, reduced in-channel, low noise, there is the phenomenon of cavitation and gasification, a small amount of leakage to the atmosphere, with abrasive media, you can use butterfly. Special working conditions in the throttle, or require strict sealing, or badly worn, low temperature (cryogenic) and other working conditions when using the butterfly valve, use a specially designed metal seal with the adjustment device to three or two eccentric eccentric Special butterfly. Butterfly valve for applications that require to be completely sealed, the gas leak test is zero, the life require a higher operating temperature -10 degrees to 150 degrees of fresh water, sewage, water, salt water, steam, gas, food, pharmaceuticals, oil and Various chemical and other pipeline. Soft seal butterfly valve for opening and closing the ventilation and dust-way pipeline regulation, widely used in metallurgy, light industry, power, petrochemical and gas pipeline systems and other waterways. Metal to metal sealing double eccentric butterfly valve suitable for urban heating, gas, water and other gas, oil, acid and alkali lines, as a regulator and the throttling device. Metal to metal sealing butterfly valve face except as a large-scale pressure swing adsorption (PSA) gas separation plant process control valves used, can be widely used in petroleum, petrochemical, chemical, metallurgy, electric power and other fields, when the gate valve, globe valve A good alternative.
From the original1gatevalve
.
Years into the future industrial valve sword favorite
In the air conditioning and heating systems, water
circulation system as the energy distribution of the water balance is
very important. The hydraulic system is a balance to meet the needs of users, saving energy consumption basis.
In the air conditioning and heating system, cold (hot) media distribution by a closed pipe system to each user. For
a well-designed systems, and the end users control valve (solenoid
valve, thermostatic valve, etc.) is 100% open should have access to the
design of water, and the end user to change the control valve opening When the desired flow and can be interfering. This
water system is a system of water balance, or imbalance is the
hydraulic system, hydraulic imbalance, also known as hydraulic
imbalance.
Hydraulic imbalance is generally divided into two kinds of static imbalance and dynamic imbalance. Static disorder, also known as the so-called steady-state offset. The system, each user in the design of state, does not match the actual flow and design flow. The hydraulic imbalance is fundamental, if not addressed, there is always affected. For
constant flow systems, such imbalances can be static or dynamic
balancing valve to solve the balance valve, except that the
instrumentation required to regulate the former, the latter do not. Dynamic disorder, also known as the stability of the so-called imbalance. The
system, some users of the water flow when the change (closed or
regulation), will cause the system to change the resistance of the
distribution, resulting in the flow of other users with the changes. This change in hydraulic imbalance is random and dynamic. Such imbalances, static balancing valve can not be solved only by dynamic balancing valve to solve.
For example: for the six floors of a building, if not
install the dynamic flow balance valve, the water system will be in the
actual operation of the dynamic imbalance. In air
conditioning cooling season, the first ~ second floor of the room will
be too cold, three to four comfortable rooms just to meet the design
temperature, five to six rooms are too hot. In contrast, in
the heating season, the first ~ second floor of the room will be too
hot, three to four comfortable rooms just to meet the design
temperature, five to six rooms were too cold. After the
installation of dynamic flow balance valve, whether it is a ~ six rooms
all or only part of the room with the use of air conditioning, all rooms
can meet the design temperature.
From the original1gatevalve
.